Herunterladen Diese Seite drucken

RK Rose+Krieger RK MonoLine R Montageanleitung Seite 110

Lineareinheit
Vorschau ausblenden Andere Handbücher für RK MonoLine R:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Assembly
Assembling optional modules > Assembling the limit switch
Applicable to
Assembling the actuator
Fig. 37: Assembling the actuator
Assembling the limit switch
Fig. 38: Assembling the limit switch
Linear unit RK MonoLine R/RK MonoLine Z/RK MonoLine Z corrosion-protected
110
Version
RK MonoLine R, Z
Size
60/80/120
Personnel:
Protective equipment:
Prerequisite:
n
The electric gear unit and/or motor (if available) are secured
against restarting.
1.
Place the actuator (Fig. 37/2) at the height of the holes below
the guide carriage (Fig. 37/3).
2.
Tighten 2 screws (Fig. 37/1):
Size
Screw size
60, 80, 120 M4
3.
Insert and position the slot stones (Fig. 38/1) in the slot of the
guide profile.
4.
Place the limit switch (Fig. 38/4) along with a holding plate
(Fig. 38/3) at the height of the inserted slot stones.
5.
Tighten 2 screws (Fig. 38/2).
Size
Screw size
60, 80
M5
120
M5
ð The limit switch is assembled.
n
Assembly staff
n
Protective clothing
n
Protective gloves
Safety shoes
n
Tightening torque [Nm]
2
Tightening torque [Nm]
4
5.9
27.10.2023

Werbung

loading