5.4.4.2
Assembling the inductive limit switch
Applicable to
Assembling the limit switch
Fig. 39: Assembling the limit switch
Adjusting the operating distance
Fig. 40: Adjusting the operating dis-
tance
Connecting the limit switch
Linear unit RK MonoLine R/RK MonoLine Z/RK MonoLine Z corrosion-protected
27.10.2023
Assembling optional modules > Assembling the limit switch
Version
RK MonoLine R, Z, Z
Size
40/60/80/120
Personnel:
Protective equipment:
Prerequisite:
n
The electric gear unit and/or motor (if available) are secured
against restarting.
1.
Insert and position the slot stones (Fig. 39/1) in the slot of the
guide profile.
2.
Place the limit switch (Fig. 39/3) along with a mounting
bracket (Fig. 39/4) at the height of the inserted slot stones.
3.
Tighten 2 screws (Fig. 39/2):
Size
Screw size
40
M4
60, 80, 120 M4
4.
Use the hexagon nuts (Fig. 40/1) to set an operating distance
of 2 mm between the inductive limit switch (Fig. 40/2) and the
roller bolt (Fig. 40/3).
5.
Have a qualified electrician connect the inductive limit switch
according to the circuit diagram.
ð The limit switch is assembled and connected.
n
Assembly staff
n
Qualified electrician
n
Protective clothing
Protective gloves
n
n
Safety shoes
Tightening torque [Nm]
1.5
2
Assembly
111