Herunterladen Diese Seite drucken

RK Rose+Krieger RK MonoLine R Montageanleitung Seite 101

Lineareinheit
Vorschau ausblenden Andere Handbücher für RK MonoLine R:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fixing slot stones
5.4 Assembling optional modules
Limited screw-in depth
Fig. 19: Pulley box
5.4.1 Assembling the motor
Applicable to
Linear unit RK MonoLine R/RK MonoLine Z/RK MonoLine Z corrosion-protected
27.10.2023
Assembling optional modules > Assembling the motor
NOTICE!
The slot stones have a limited screw-in depth!
Adjust the size and length of the screws to the
slot stones used.
Never screw the screws in as far as the bottom
of the slot stone(s).
3.
Carefully tighten the screw for every slot stone:
Size
Screw size
40
M6
60, 80, 120 M8
ð The linear unit is installed on the substrate.
NOTICE!
Limited screw-in depths in the pulley boxes!
When using optional modules from other man-
ufacturers, adhere to the maximum screw-in
depth in the pulley boxes (Fig. 19/1):
RK MonoLine Z 40: 10 mm
RK MonoLine Z 60/80: 14 mm
RK MonoLine Z 80
Adjust the size and length of the screws to the
pulley boxes being used.
Version
RK MonoLine Z, Z
Size
40/60/80/120
Assembly
Tightening torque [Nm]
10
25
: 14 mm
101