Appendix
Emissions test
RF emissions CISPR 11
RF emissions CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/flicker emissions
IEC 61000-3-11
10/2017
8.3
Wellsystem MEDICAL / MEDICAL_PLUS:
EMC information
8.3.1
Table 201: Guidance and manufacturer's
declaration – electromagnetic emissions
The massage unit has been designed for use in the electromagnetic sur-
roundings listed below. The operator of this equipment must ensure that it is
only used in one of these surroundings.
Compliance
Group 1
Class B
Class A
complies
Electromagnetic environment – Guidance
The massage unit uses RF energy only for its
internal function. Therefore, its RF emissions
are very low and are not likely to cause any
interference in nearby electronic equipment.
The massage unit is suitable for use in all estab-
lishments, including domestic establishments
and those directly connected to the public low-
voltage power supply network that supplies
buildings used for domestic purposes.
Obligations according to Subclause 6.2.2 of
EN 61000-3-11:2000 have to be considered.
Especially the line impedance of 0.14 Ohms
must be guaranteed for pulse massaging.
Installation instructions 63/68