Liquiport 2000 Ex
Switch (only for an
active switching pro-
gramme)
Creating programmes - Main programmes
Sample
Distribution
Start programme
Stop programme
Mode
Synchronisation
Creating programmes - Switching programmes
Switch
Sample
Endress+Hauser
↵
Set
Day:
↵
Programme selection
Switch between main and switching programmes on two specific times
Switch
a day.
Week:
Switch between main and switching programmes on three specific
weekdays.
Q greater:
Switch when flow greater than limit value.
Q smaller:
Switch when flow smaller than limit value.
External:
Switch on external signal.
↵
Set
Time:
↵
Creating programmes
Sampling acc. to time;
↵
Programme 1,2,3,4
Quantity:
↵
Sample
Sampling acc. to volume (connect volume signal!).
Mode
Ext. sig.:
Sampling on external signal (connect signal input!).
Flow
Sampling acc. to flow (connect volume signal).
↵
Set
Time:
↵
Creating programmes
Bottle change after a specific time.
↵
Programme 1,2,3,4
Number:
↵
Distribution
Bottle change after a specific number of samples.
Sample
Ext. sig.:
Bottle change on external signal (connect signal input!).
↵
Set
Aut:
↵
Creating programmes
Press the Aut key to start the programme.
↵
Programme 1,2,3,4
Time:
Start-Stop
Start the programme at a settable time.
↵
Set
Prog. end:
↵
Creating programmes
Programme end on completion of the set programme.
↵
Programme 1,2,3,4
Time:
Start-Stop
Programme end after settable time.
None:
Continuous operation.
↵
Set
Cont.:
↵
Creating programmes
Continuous operation.
↵
Programme 1,2,3,4
Day:
Start-Stop
Operation at 2 settable times per day.
Week:
Operation on 3 settable days per week.
Interval:
Settable operating duration in settable intervals.
↵
Set
Aut-button
↵
Creating programmes
Time:
↵
Programme 1,2,3,4
Sampling times and bottle change are synchronised.
Synchronisation
Time+bot.:
Synchronisation of sampling and distribution. Fixed times are assigned
to the bottles.
↵
Set
Sample: sampling type in the switching programme.
↵
Creating programmes
Distribution: distribution mode for the switching programme.
Switch 1,2
↵
Set
Time: sampling acc. to time.
↵
Creating programmes
Volume: sampling acc. to volume (connect volume signal!).
↵
Switch 1,2
Ext. sig.: sampling on external signal (connect signal input!).
Sample
Flow: sampling proportional to flow (connect quantity signal)
6 Commissioning
Day
Time
Time
Aut
Prog. end
Cont.
Aut-button
-
Time
77