6. Commissioning, operation

6.9.4 Ref. sensor list

The CPH6000 pressure calibrator supports up to 10 CPT6000 reference pressure sensors.
With the [▲] or [▼] button, select the sensor.
Confirm by pressing [ENTER]
EN
Currently connected CPT6000 reference pressure sensor
1
Sensor list of the supported CPT6000 reference pressure sensors
2
(calibrated with the instrument)
Data of the sensor which has been selected using the cursor (calibration
3
date: year/month/day)

6.9.5 CPH configuration

With the [▲] or [▼] button, select menu item.
Input via numeric keypad.
Confirm by pressing [ENTER].
[CLEAR] deletes the input.
This menu section lists general instrument settings, such as:
Temperature:
1
Input possibility for an ambient temperature
HeightDiff:
2
Input possibility for a height difference between reference pressure sensor
and test item, used in the automatic correction.
Calculating a pressure based on a medium column.
If a significant height difference exists between the CPT6000 reference
pressure sensor and the test item, then the pressure difference, based on a
medium column, can be compensated automatically via the menu.
The standard height difference between test item and CPT6000 reference pressure sensor is 98 mm [3.86 in].
Language:
3
Selection of the menu language (German/English/French/Spanish/Italian)
Date:
4
Date of the system clock (year/month/day)
Time:
5
Time of the system clock (hours/minutes/seconds)
Brightness:
6
Brightness of the backlighting of the display
Powersave:
7
Automatic switch-off time for backlighting and internal auxiliary supply for test items with DC 24 V.
If the instrument is idle for the set switch-off time (no buttons pressed and no interface communication), then the
backlighting and the voltage supply for the test item with DC 24 V will be switched off until any button is pressed or the
instrument is addressed over the interface.
40
WIKA operating instructions, pressure calibrator model CPH6000
..Ref. Sensor-list
362A
Current
1
01 362A
06 ----
02 Rp52
07 ----
2
03 Kd35
08 ----
04 Rp56
09 ----
05 ----
10 ----
R.-Start:
0.000
Range-End:
10.000
Unit:
bar
3
Cal-Dat.:
2011/05/10
Class:
0.025
..CPH-Configuration
1
20.0
Temperature:
HightDiff:
0 mm
2
Language:
German
3
4
Date:
2011/05/10
13:22:51
Time:
5
Brightness:
80 %
6
7
Powersave:
15 min
Batterylevel:
100 %
8
Input of current term
°C