Herunterladen Inhalt Inhalt Diese Seite drucken

Airwell WELLEA SPLIT A R3 Installationsanleitung Seite 37

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 148
Item
Description
1
Solar energy kit signal cable
2
User interface cable
3
Room thermostat cable
Solar pump control cable
4
Outside circulation pump control cable
5
6
DHW pump control cable
7
SV2: 3-way valve control cable
8
SV1: 3-way valve control cable
9
Booster heater control cable
10
Power supply cable for indoor unit
(a) Minimum cable section AWG18 (0.75 mm
(b)The thermistor cable are delivered with the unit:if the current of the load is large, an AC contactor is needed.
Please use H07RN-F for the power wire, all the cables are connect to high voltage except for thermistor cable and cable
for user interface.
Equipment must be grounded.
All high-voltage external load, if it is metal or a grounded port, must be grounded.
All external load current is needed less than 0.2A, if the single load current is greater than 0.2A, the load must be controlled
through AC contactor.
"AHS1" "AHS2", "A1" "A2", "R1" "R2" and "DFT1" "DFT2" wiring terminal ports provide only the switch signal.
Please refer to image of 8.8.6 to get the ports position in the unit.
Plate heat exchanger E-Heating tape and Flow switch E-Heating tape share a control port.
Field wiring guidelines
Most field wiring on the unit is to be made on the terminal block inside the switch box. To gain access to the terminal block,
remove the switch box service panel.
Switch off all power including the unit power supply and backup heater and domestic hot water tank power supply (if
applicable) before removing the switch box service panel.
Fix all cables using cable ties.
A dedicated power circuit is required for the backup heater.
Installations equipped with a domestic hot water tank (field supply) require a dedicated power circuit for the booster heater.
Please refer to the domestic hot water tank Installation & Owner's Manual.
Lay out the electrical wiring so that the front cover does not rise up when doing wiring work and attach the front cover
securely.
Follow the electric wiring diagram for electrical wiring works (the electric wiring diagrams are located on the rear side of door
2.
Install the wires and fix the cover firmly so that the cover may be fit in properly.
8.8.3 Precautions on wiring of power supply
Use a round crimp-style terminal for connection to the power supply terminal board. In case it cannot be used due to
unavoidable reasons, be sure to observe the following instructions.
-
Do not connect different gauge wires to the same power supply terminal. (Loose connections may cause overheating.)
-
When connecting wires of the same gauge, connect them according to the figure below.
AC/DC
Required number of conductors
AC
2
AC
5
AC
2
AC
2
AC
2
AC
2
AC
3
AC
3
AC
2
AW-WHPSA0406-N91
2+GND
AW-WHPSA0810-N91
AC
AW-WHPSA1216-N91
4+GND AW-WHPSA1216-N93
).
2
NOTE
WARNING
36
Maximum running current
200mA
200mA
200mA(a)
200mA(a)
200mA(a)
200mA(a)
200mA(a)
200mA(a)
200mA(a)
13.5A
13.5A
13.5A
13.3A

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis