Error messages

5
Error messages
In case of anomalies or errors, the MSA 4.0 (MSA 4.1) will pop up with a specific message
useful to identify the possible issue. The related number will be even tracked within the
welding protocol, to give evidence of the accident.
The error message appears on the display with the following format:
The table below summarizes all the messages managed by the electro-fusion unit, with a
brief explanation of the possible causes.
E
DISPLAY INDICATION
1
MAINS VOLTAGE TOO LOW
2
MAINS VOLTAGE TOO HIGH
3
OUTAGE DURING LAST FUSION
4
FUSION INTERRUPTED WITH STOP BUTTON
5
AMBIENT TEMP. TOO LOW
6
AMBIENT TEMP. TOO HIGH
7
INTERNAL TEMP. TOO LOW
8
INTERNAL TEMP. TOO HIGH
9
FITTING RESISTANCE TOO LOW
10
FITTING RESISTANCE TOO HIGH
11
FUSION VOLTAGE TOO LOW
12
FUSION VOLTAGE TOO HIGH
13
FUSION CIRCUIT INTERRUPTED
14
FUSION CURRENT TOO HIGH
15
UNIT RANGE EXCEDEED
16
SYSTEM ERROR
17
INTERNAL TEMP. TOO HIGH (DIAM.>=315)
ALERT! THE UNIT REVISION HAS EXPIRED
ALERT! RENTAL TIME HAS EXPIRED
MEMORY EMPTY
ERROR n: 4
FUSION INTERRUPTED
WITH STOP BUTTON
COMMENT
Generator voltage/freq. below the threshold
Generator voltage/freq. above the threshold
Power cord disconnected during last fusion
Fusion stopped by the user
Temp. sensor detected a value below the threshold
Temp. sensor detected a value above the threshold
EF unit cannot fuse, since it is too cold
EF needs to cool down, since it is too hot
Fitting faulty or different from that one specified in the
barcode
Fitting faulty or different from that one specified in the
barcode
Not enough power from mains
Internal circuit not calibrated or faulty
Power cord or output cables detached during welding
Fitting broken or circuitry not calibrated or faulty
Fitting not supported
Electronic faults
EF needs to cool down, since it cannot ensure the
fusion process can be completed successfully for large
diameters
Calibration needed
Rental time expired
No data protocols stored in the unit