Data Management
To enter the data management menu, press MENU, select DATA RETRIEVAL by ()() and
press START/OK ( I ) to see the possible options. Then the buttons ()() allow to scroll the
different options; press START/OK ( I ) to jump to the chosen one.
(*) Visible only with administrator rights
There are several possibilities:
view the welding data on the display,
export the protocols to an USB memory
erase the stored protocols
The options depend on user permission: a user in possession of the supervisor badge can
access all the menus, while a standard user can only browse and export the existing
protocols.
4.1
View Protocols
VIEW PROTOCOLS shows briefly the stored welding protocols on the display. The most
recent protocol appears as first.
The buttons ()() allow to scroll up and down the list of protocols. Pressing STOP/ESC (O)
the user can go back to DATA RETRIEVAL menu again.
24
DATA MANAGEMENT
VIEW PROTOCOLS
VIEW PROTOCOLS DETAILS
DATA MANAGEMENT
EXPORT PROTOCOLS
SAVE ALL PROTOCOLS TO USB MEMORY
STICK IN PDF OR CSV FORMAT
DATA MANAGEMENT
DELETE PROTOCOLS
DELETE PERMANENTLY ALL PROTOCOLS
FROM THE INTERNAL MEMORY
VIEW PROTOCOLS
Vo=40V
N 13/5000
Vin=230V
T=25°C
ERR 0 = PROCEDURE OK
Bedienungsanleitung MSA 4
22°C
09:16 11.03.14
22°C
09:16 11.03.14
22°C
(*)
09:16 11.03.14
09:16 11.03.14