QuantumX driver for CANape
Fig. 5.15:
Edit time source dialog
Possible settings for the time source type
Auto: Uses the internal time source of the module or synchronizes with the
master module or CX27, if present and connected via FireWire. The master
module is the module with the highest UUID (serial number).
NTP: Enables synchronization via Ethernet. The module obtains the actual
time from this time server, taking into account the runtime of the signal. The
achievable minimum synchronization deviations are approx. 100 s.
Important
After the time source has been set to NTP, the relevant module must be
restarted (switch off and then switch back on again). The process requires up
to two hours after the initial activation to reach a settled condition. Leave the
module switched on after activation until the module LED lights up green (the
LED lights up orange during the process or when the set synchronicity
threshold is exceeded). This process usually only takes two minutes after the
next switch on.
EtherCAT (only with a CX27 module): This version is currently not supported
in combination with CANape.
IRIG: This version is currently not supported in combination with CANape.
The QuantumX filters have a propagation time (phase delay) and can
therefore influence the synchronicity of the measured values.