Herunterladen Inhalt Inhalt Diese Seite drucken

Start And Stop Levels; Direction Of Rotation - Grundfos AP80-100 Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für AP80-100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 54
Minimum liquid level
Position
Description
1
Minimum liquid level
P
1
2
3
S3 operation
Position
Description
1
Operation
2
Stop
3
Duty cycle
14

6.2 Start and stop levels

Start and stop levels can be adjusted by changing the
free cable length of the float switch.
Long free cable = large difference in level.
Short free cable = small difference in level.
To prevent air intake and vibrations, install the
stop level switch, so the pump is stopped before
the liquid level reaches the upper edge of the
clamp.
Install the start level switch, so the pump is
started at the required level. The pump must
1
always be started before the liquid level reaches
the bottom of the inlet pipe.
Start and stop levels
t
Position
1
2
3

6.3 Direction of rotation

All single-phase pumps are factory-wired for the
correct direction of rotation. Before starting up three-
phase pumps, check the direction of rotation. An
arrow on the stator housing indicates the correct
direction of rotation.
Procedure 1:
Description
Alarm
Start
Stop
The impeller rotates clockwise. When
started, the pump jerks counterclockwise.
1
2
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis