Herunterladen Inhalt Inhalt Diese Seite drucken

Fault; Troubleshooting - Angelo Po 1N1FAE Bedienshandbuch

Gasherd
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
The appliance has been tested before being put
into service. The information provided below
is intended to assist in the identifi cation and
correction of any anomalies and malfunctions
which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical
knowledge or skill is required, and so they
must only be carried out by qualifi ed staff with
recognised experience acquired in the specifi c
sector of operation.
Faults
Smell of gas.
The pilot light goes out.
The fl ame is yellow.
Burner control knob is stiff .
The heating elements do not
come on.
GB
The appliance does not
heat up to the set
temperature.
3320050_ut_GB_rev.1

FAULT

TROUBLESHOOTING

For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Causes
Occasional leak because
fl ame has gone out.
The thermocouple has not
warmed up enough.
Burner dirty.
Gas control valve malfun-
ction.
Electrical connection not
made correctly.
Safety thermostat tripped.
Switch faulty.
Thermostat faulty.
- 14 -
Important
Remedies
Turn off the gas supply tap and
ventilate the room.
Make more attempts to light
the fl ame.
Clean the burner.
Contact the after-sales service.
Check the connection of the
electrical wires.
Contact the after-sales service.
Carry out the appliance reset.
Contact the after-sales service.
Replace the switch.
Contact the after-sales service.
Replace the thermostat.
Contact the after-sales service.
ENGLISH

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

1t1fae1n1faae1t1faae

Inhaltsverzeichnis