Caution - Warning
Before doing any work, cut off the mains
electricity supply.
The manufacturer has tested the appliance with
its own mains gas, identifi ed by the sticker ap-
plied to the nameplate.
If the type of gas to be connected is diff erent
from that used for testing, proceed as follows.
Turn off the gas supply tap (A).
1)
Change the top burner nozzles (see page 16-
2)
17).
Change the top burner pilot light nozzles (see
3)
page 17).
Adjust the minimum settings of the gas control
4)
valves of the top burners (see page 14).
Remove the sticker from the nameplate and
5)
apply the new one to identify the gas being
used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
Important
Before it is put into service, the system must
be tested to check the operating conditions
of every single component and identify any
malfunctions. In this stage, it is important to
check that all health and safety requirements
have been complied with in full.
To test the system, make the following checks:
Check that the mains voltage is the same as
1)
that of the appliance.
Operate the appliance's circuit-breaker to
2)
check the electrical connection.
Turn on the gas supply tap and check that the
3)
connections are right.
Check that the mains gas is the same as that
4)
used for commissioning of the appliance,
and carry out the conversion procedure if
necessary (see page 13).
3320050_inst_GB_rev.1

CONVERSION OF GAS SUPPLY

TESTING OF THE APPLIANCE

5)
6)
7)
8)
9)
After testing, if necessary instruct the user in all
the skills necessary for putting the appliance
into operation in conditions of safety, in accor-
dance with legal requirements.
- 13 -
A
Check that the hob burners are igniting cor-
rectly and their combustion.
Check the gas pressure and fl ow-rate at
minimum and maximum settings and adjust if
necessary (see page 7).
Check that the safety device is operating
correctly.
Check that there are no gas leaks.
Check that the nameplates specify the correct
gas for the country of use.