TROUBLESHOOTING
The appliance has been tested before being put
into service.
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and malfunctions which might occur during
use.
Faults
Smell of gas.
The pilot light
does not ignite.
La spia pilota non rimane accesa.
The pilot light goes out.
Burner control knob is stiff.
FAULT
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
Causes
Occasional leak because
flame has gone out.
Air in pipelines due to long
period out of use.
The thermocouple has not
warmed up enough.
The flame is yellow.
Gas control valve malfunction.
- 11 -
Remedies
Turn off the gas supply tap
and ventilate the room.
Make more attempts
to light the flame.
Make more attempts to light
the flame.
Clean the burner
Important
Contact the after-sales
service
6
IT
GB
DE
FR
ES
English