Important
Before making any type of adjustment, acti-
vate all the safety devices provided and deci-
de whether staff at work and those in the vi-
cinity should be informed.
In particular, turn off the gas supply tap, cut
off the electricity supply using the master
switch and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (TOP BURNERS)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Remove the injector (D) and replace it with
4)
the one suitable for the type of gas in use (see
table at back of manual).
Fully screw the injector.
5)
After making the setting, seal the screw with
6)
paint.
Replace the control panel (B) and the knob
7)
(A) on completion of the operation.
GB
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Undo the screw (D).
4)
Set the burner mount (E) at a distance of 17
5)
mm , and tighten the screw (D).
Replace the control panel (B) and the knob (A)
6)
on completion of the operation.
3320050_inst_GB_rev.1
ADJUSTMENTS
INSTRUCTIONS AND WARNING FOR ADJUSTMENTS
ADJUSTING TOP BURNER PRIMARY AIR (4 KW)
Important
These adjustments are only required if the
type of gas to be connected is diff erent from
that used for testing after the conversion
procedure has been carried out (see page13).
Caution - Warning
Adjustments must be carried out by authori-
sed, qualifi ed staff , in accordance with the re-
levant legal requirements.
A
B
A
B
- 14 -
C
C
C
C
D
D
ENGLISH