RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed. In particular,
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING
Important
This adjustment is only required if the type of
gas to be connected is different from that
used for testing after the conversion
procedure has been carried out (see
page 15). Before making this adjust-
ment, check that the gas supply pres-
sure is the same as the rated pressure for the
type of gas in use (see table at back of manu-
al).
IT
GB
DE
FR
ES
English
ADJUSTMENTS
B
A
- 16 -
turn off the gas supply tap and prevent ac-
cess to all devices which might cause un-
expected health and safety hazards if
turned on.
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - After making the setting, seal the screw with
paint.
6 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
C
8
D
IDM-39608800600.tif