8 The Keyboard Mode for Changing Points and Signals
The table is selected by allocating the first key
pair the address number 0 in keyboard mode and
confirming with [↵]. When the following display is
shown the point address table is activated.
Using the "special option" in the basic setting
menu, each key pair in table mode can be alloca-
ted a desired point number (see supplement 1 of
the manual with the list of special options; here
SO810).
8.5

Setting the Switching Time

As long as a key of the keyboard to change a
point or signal continues to be depressed, then
the corresponding command will be continue to
be sent.
In order to be sure that even with a short pressu-
re on the key will successfully carry out the swit-
ching function, or on the other hand, that a swit-
ching impulse if operated for too long a time will
not damage a point or receiver module, the
TWIN-CENTER has a built-in maximum and mini-
mum switching time.
As set by the factory, the values for the minimum
and maximum switching time are both set to 0.05
s. Both parameters can be changed in the TWIN-
CENTER basic setting menu.
Values between 50 and 9999 ms can be input.
The electrical accessory receiver module 6852
has an integrated minimum switching time of
approx. 0.5s which is sufficient for the minimum
value.
ADVICE
For DCC receiver modules, the switching
time of the receiver can only be influen-
ced when it is not set to "continuous ope-
ration".
And here is how to do it:
• Press the [menu] key
• Press the [mode] key
• Search through using the [↓] key until
the entry "Access.Setting" is reached
122
01.03.2007
13:58 Uhr
Seite 122
• Continue with the [→] key
• Search through using the [↓] key until
the entry "Switch times" is reached
• Continue with the [→] key
SwTime
Min:
Max:
in mx: .100
3000
• In the first entry position under "Min"
(minimum time) shows the least time
that a point receiver will be switched by
the TWIN-CENTER; also the shortest
operation of a point address
If the value "0" is set, then the function
will be ignored and the switching impul-
se will be actually as long as the key is
depressed.
• A new time can be set by using the key
[↵]
• Using the [→] key the cursor will move
to the right entry position
• Under "Max" (maximum time) the time
will be set to activate a point receiver,
even if the command to deactivate the
point receiver fails.
If the value "0" is set, then the function
will be ignored and the switching impul-
se will be actually as long as the key is
depressed.
• A new time can be set by using the key
[↵]
• Return to running with the [menu] key
ADVICE
Should both values need to be altered,
each new value must be confirmed by
pressing the [↵] key.
If the "min"-value is input as larger than
the "max"-value, then this will not be
accepted.