In DC operation mode, means that as the knob is
rotated to the right, away from the central off
position, the loco will correspondingly gain speed
in that direction. As the knob is turned back
again. i.e. back to the central off position, so the
speed of the loco will be reduced until it comes to
a halt. If the knob is further turned to the left, the
loco will then accelerate away in the opposite
direction.
Once it reaches its maximum speed setting then
any further rotation of the knob has no effect, i.e.
the maximum speed level remains unaltered in
the display. Also, the control knob cannot be set
immediately in the opposite direction, the speed
level indicator will remain at level 0. Following a
pause of about 1 seconds, then speed levels in
the opposite direction can be set. This pause is
necessary because the endless knob has no cen-
tral zero setting like a conventional controller.
In the operational mode, then a light pressure on
the control knob will result in an emergency stop
specific for this loco (FMZ, DCC).
AC controller mode
The AC control knob setting
mode is for those who prefer to
control their locomotives as they
0
100
would do with a standard 3-rail
AC controller.
In this method of operation, the speed is dictated
by rotating the knob to the right, and reduced by
turning it to the left. Once the maximum speed or
the off position been reached, then any further
rotation of the knob in the same direction will
have no further effect. The maximum speed or
the off position will be kept.
The running direction, in this operational mode,
will be altered by a light pressure on the control
knob. Operating this reverser switch whilst the
loco is running will result in an emergency stop for
this loco (FMZ, DCC), as well as a simultaneous
reversion of the running direction (watch the
arrow on the display). By rotating the knob again
to the right, then the loco will now run in the
opposite direction.
01.03.2007
13:57 Uhr
Pre-setting
As delivered, the DC controller mode is activated.
Alterations can be made from the basic setting
menu of the TWIN-CENTER.
And here is how to do it:
7.3.2
Two different styles can be selected to indicate
the speed of vehicles in the display.
Absolute Display*
A direct indication of the speed is shown in speed
steps, according to the data format 0 -14, 0-15,
0-27, 0-28, or 0-126.
Percentage Display
Independent of the data format, the display
shows the speed as a percentage of the maxi-
mum speed.
And here is how to do it:
Seite 109
7 The Controller
• Press the [menu] key
• Press the [mode] key
• Using the [↓] key, search through until
you find the entry "User Interface"
• Further with the key [→]
• Use the [↓] key until entry
"Speed knobs" is found
• Further with the key [→]
• Search through with the [↓] key until the
desired entry (DC or AC style knob)
is found
• Confirm the input with the [↵] key
• Return to operation with the [menu] key

Speed step display

As delivered, "Absolute" is already pre-set.
• Press the [menu] key
• Press the [mode] key
• Using the [↓] key, search through until
the "User Interface" entry
• Further with [→] key
• With the [↓] key until the entry "loc
speed disp"
• Further with [→] key
• Using the [↓] search through until you
find the desired entry
• Confirm the input by using the [↵] key
• Back to operation by using the [menu]
key