ADVICE
The further a loco runs away from the
place at which the power is fed into the
track, then the slower it will run - and on
really large layouts a loss of power is una-
voidable. It is recommended therefore
that the power should be fed into the
track at several places around the layout.
It is better to set out a ring main (with wire
6982), and then from this ring main,
connect into the track at roughly 3 metre
intervals. Please ensure however, that you
connect them up with all the same
polarity.
Track
The trackwork (2 rail) is connected onto clamps 3
and 4 of the clamp plug for socket 1.
violet-white
1 2 3 4 5 6
Programming Track
The programming track is one section of track
that is set up and specially reserved for program-
ming and reading the coding of loco decoders.
VERY IMPORTANT
The track must be absolutely isolated
from the running track. In the course
of programming, the isolating breaks
should not be overbridged (by the
bogies of an illuminated coach for
example).
01.03.2007
Connection for
2 rail track
violet
13:57 Uhr
Seite 99
4 The connections of the TWIN-CENTER
violet
violet-white
1 2 3 4 5 6
The track is connected to clamps 1 and 2 of the
clamp plug for socket 1.
In the basic setting of the equipment (chapter
10.1) it is shown how this piece of track is hand-
led by the TWIN-CENTER. Either solely as a 'pro-
gramming track' or 'automatic', which means for
example that the designated track will only be
used whilst programming, or used as a normal
piece of running track. The switching arrangement
is carried out automatically by an internal relay.
IMPORTANT
If the wiring of the programming track
are swopped over, then a short circuit
will occur when the isolating breaks
between the programming track and
the running track are run over and the
TWIN-CENTER will switch itself off
displaying the error indication "short
circuit".
4.2
Connecting the TWIN-
BOOSTER (6807) and
FMZ-BOOSTER (6805)
The TWIN-BOOSTER (6807) and/or the FMZ-
BOOSTER (6805) are connected into socket 2.
As the flat cable band joins socket 2 of the TWIN-
CENTER with the TWIN-BOOSTER (see instruc-
tions for use of the TWIN-BOOSTER), then the
plug must be correctly inserted so that the cable
between the TWIN-CENTER and the TWIN-BOO-
STER 6807 runs in an upwards position.
Shape and position of the flat cable band.
Connection of the
programming track
99

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Twin-control 6822

Inhaltsverzeichnis