14 Basic Settings

14.8 Programming Track

It will be decided here whether the programming
track in normal operation will be fed with power
or will have no power. The programming power
will be fed to the track whilst programming.
Possible settings: automatic (power onto the
programming track in normal operation) or
Solely programming track (no power in normal
operation).
Factory setting: automatic
Comprehensive description see chapter 10.1

14.9 Interface

14.9.1 Data Rate

Here we can decide on the data transfer rate of
the serial connector port of the TWIN-CENTER;
Possible settings: 2400, 4800, 9600, or 19200
bits/sec.
Factory setting: 2400
Comprehensive description see chapter 11.1.1

14.9.2 Syntax

If the TWIN-CENTER is to be run with a compu-
ter (PC or MAC), then the computer and the
TWIN-CENTER will need to use a common lan-
guage, a "Syntax", between each other in order
to communicate. Besides the TC-Syntax and the
IB-Syntax the software V1.100 also recognises
the additional LocoNet-Syntax. The Syntax
which is to be used will be dictated by your com-
puter program which to choose to operate the
layout.
Here you can decide on the syntax of the data
transfer rate between the computer and TWIN-
CENTER. Possible settings: TC-Syntax or IB-
Syntax or LocoNet-Syntax.
Factory setting: LocoNet-syntax
Comprehensive description see chapter 11.1.2

14.9.3 Computer

These parameters set out whether the connected
computer is an IBM compatible (PC) or and
Apple-Macintosh (Mac) or whether no computer
is connected.
Factory setting: PC
Comprehensive description see chapter 11.1.3
140
01.03.2007
13:58 Uhr

14.10 s88 Setting

Here we decide on the number of connected s88
modules (number from 1 to 31).
Factory setting: 8
Comprehensive description see chapter 12

14.11 Special Options

The possible special options are comprehensive-
ly described in supplement A1 (see also chapter
8.2).

14.12 Software-Version

This menu shows the serial number of the equip-
ment and the version of the system software it
contains. Input is not possible.

14.13 Start Mode

This parameter decides on which basic data the
equipment starts with: Possible settings:
no loco data (start without data of the previous
operation),
auto: Speed = 0 (start with all data from the pre-
vious operation, but with speed of all locos set at
0),
auto + speed (start with all data from previous
operation and all locos to run at the previously
allocated speeds).
Factory setting: auto + speed
Comprehensive description shown in chapter
7.14

14.14 Reset

This menu serves to reset several sections of the
TWIN-CENTER: Possible settings: configuration,
loco data format or points.
• Configuration
• Loco Data Format or
• Points
Configuration
All alterations to the basic setting menu will be
cancelled. All alterations to the special options
will be taken back. The input for the selected lan-
guage will remain.
Seite 140