Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Of Transmitter To Flowmeter Sensor; Connection Of Transmitter To Flowmeter Sensor In; Zone 1 / Div. 1 - ABB CoriolisMaster serie Inbetriebnahmeanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.6.3

Connection of transmitter to flowmeter sensor

FCT330, FCT350 transmitter to FCB330, FCB350 flowmeter sensor
92 91 85 86 87 88 89 90 93 94 95 96
SE
85
86
87
88
SE
96
95
94
93
Fig. 24
1 Equipotential bonding (PA)
Terminal
Corresponding wire color
85
White
86
Brown
87
Green
88
Yellow
89
Black
90
Violet
IMPORTANT (NOTE)
The precise position of the PA terminals may vary according to the device type. Each terminal is marked accordingly. When the
FCT330, FCT350 transmitter is connected to the FCB330, FCT350 flowmeter sensor, the transmitter must also be connected to
"PA".
The following flowmeter sensor / transmitter combinations are permitted:
— FCB330 flowmeter sensor with FCT330 transmitter
— FCB350 flowmeter sensor with FCT350 transmitter
89
90
95
96
93
94
91
92
90
89
88
87
86
85
91
92
Function
Sensor 1
Sensor 1
Sensor 2
Sensor 2
Temperature
Temperature
1
1
Terminal
Corresponding wire color
91
Gray
92
Pink
93
-
94
-
95
Blue
96
Red
CoriolisMaster FCB330, FCB350 | CI/FCB300-X1 EN - 25
FCT330
FCT350
1
1
FCB330
FCB350
FCB330 - A1/F1
1
FCB350 - A1/F1

(Zone 1 / Div. 1)

Function
Driver
Driver
Not used
Not used
Temperature
Temperature
G10329

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Coriolismaster fcb330Coriolismaster fcb350

Inhaltsverzeichnis