Herunterladen Inhalt Inhalt Diese Seite drucken

GM-Racing GENIUS 90 Bedienungsanleitung Seite 36

Brushless + brushed
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

#6 ABS (0 = OFF, 1 = ON)
The ABS braking function prevents cars from swerving when the brakes are applied. The ABS brake
pulses between the max. braking action as assigned by the throttle stick, and the BRAKEMAX value.
Factory setting: 0 = OFF,
Recommended settings: 1 = ON, BRAKEMIN 20-40%, BRAKEMAX 70-100%
#7 AUTOGAS (automatic throttle)
"Idle" in the throttle position "neutral" is a sensible setting especially for the standard classes where easy
taxiing is desired. AUTOGAS will be automatically disengaged after a few seconds to avoid an early
start on the starting line, with the model driving off slowly, and to save battery power during longer stops.
For AUTOGAS to work it is necessary to set AUTOBRAKE to 0%!
Factory setting: 0, recommended values for the standard classes: 1 - 20
#8 SOFTGAS (soft start) (0-10 by SET-button, 0-200 by GMVIS-Commander)
The smaller the pre-set value the softer the controller will speed the motor up.
In case the motor doesn't speed up as desired, or gets stuck at lower RPMs than desired, then
immediately switch the motor off and reduce the SOFTANLAUF value (i.e. increase run-up time) until
the motor accelerates smoothly. In normal conditions all motors should run up smoothly with the factory
settings.
1 = run-up time 4 sec
2 = run-up time 2 sec
3 = run-up time 1.33 sec
4 = run-up time 1 sec (for airplane)
...
16 = run-up time .22 sec (for acrobatic airplane)
...
40 = run-up time .1 sec
60 = run-up time 68 ms
100 = run-up time 40 ms
200 = run-up time 20 ms
#9 TIMING (0-4) (only for sensorless brushless motors!)
If you want to achieve the maximum efficiency you should adjust the timing.
In most cases the factory setting will achieve best efficiency.
A timing of 30° is recommended when run-up problems are being encountered.
0 = 0° timing
1 = 7.5° timing (recommended for slottless 2 pole brushless motors)
2 = 15° timing
4 = 30° timing (recommended for slotted stators, EFRA, IFMAR, DMC motors and brushless motors
with 8-16poles)
Timing with hall sensors (only programmable with the PC-software:
0, 1 = original motor timing (mechanical fixed on the motor)
2
= +15° Timing, mechanical timing + 15° Timing
3, 4 = +30° Timing, mechanical timing + 30° Timing