10 Controls and indicators

5
Pushbutton Close door / Minus
6
Pushbutton Menu / Confirm (Teach-in run)
7
Pushbutton Open door / Plus
8
Display
8
5
Messages of the display (8)
Status messages
A
B
A door in end position OPEN
B door between the two end positions
C door in end position CLOSED
Status messages
During door movement in OPEN direction
C => B => A...
During door movement in CLOSE direction
A => B => C...
L4 Set end position OPEN
L3 Reference run CLOSE and set end position CLOSED
L2 Teach-in run OPEN (load values)
L1 Teach-in run CLOSE (load values)
Err Error and error number (flashing)

11 Connections

1
EMERGENCY stop (green)
2
Photo cell (yellow)
3
Pulse
1
2

12 Installation preparations

Please note: Check that the door is working properly
and running smoothly, and adjust if necessary. The
spring tension of the door must be set in such a way that it is
stable and can be opened and closed by hand smoothly and
without jolting.
• Standard and appropriate
50 cm away from the fastening position for the head of the
operator.
(For information on fuses, see the technical data.)
14 / 206
res.
6
7
C
3
shock-proof socket approx. 10 -
• Only install the door operator in dry garages.
Make sure the installation set for the connection is ready on
the door type that is being attached and/or install it according
to the relevant manual.
ATTENTION: Be aware that the operator assembly is
a heavy equipment. Use appropriate T-support for
holding the operator in place during fixing (See page 201 (I))

13 Installation

See instructions for installation on page ff 196.
The head of the operator can be turned by 90° to the running
rail respectively as required (See page 197 (E)).
Installation step D, page 197:
1. Tighten the toothed belt's clamping nut until the toothed
belt no longer rests on the guide rail (equivalent to
dimension X).
2. Use the clamping nut (dimension B) to increase the
toothed belt tension to correspond to the length of the door
operator (A).
I

14 Commissioning

Once installation is complete
• Slowly open the door by hand until you hear the slide snap
in.
• Make connection to mains, display flashes alternately with
L and 4. The door operator lamp flashes in intervals of 4.
• Teach in the door operator (see Chapter 15).
• Teach in the remote transmitter (see Chapter 16).
• Carry out a safety inspection (see Chapter 9).

15 Teaching in the door operator

ATTENTION: No protection is provided by the load
switch-off whilst the door operator is being taught
in.
Note: Teaching in is only possible during initial installation or
after resetting the door operator. Do not press any keys
during the teach-in procedure.
Preparation: Connect the door to the door operator.

Teaching in with a remote transmitter

At the time of delivery and after resetting the door
operator, the remote transmitter supports the following
functions:
• A Safety control operation and fine adjustment "OPEN"
• B Safety control operation and fine adjustment "CLOSE"
• C and D Confirmation (storage)
Once the door operator has been taught
in, key A is used for remote control and
the other keys can be used to control
other similar door operators or other
radio receivers.
Teaching in
• Press and hold down key A; the door moves in the open
direction.
• When you reach the desired end position "OPEN", release
key A. (You can make corrections with key B.)
IP2285 11/2017