Do not connect any other consumers to the supply line!
When power packs or power supply units are being
used, note that the output voltage is between 11 V
and 15 V and the alternating current ripple is < 1.2 Vpp. The
Truma battery charger NT 12/ 3-18 (part no. 39901-01) is
recommended for connecting multiple 12 V devices. This
charger (with a charging current of 18 A) is suitable for
charging lead-acid or lead-gel batteries. Other chargers may
be used only with a 12 V battery as a buffer.
For saving the battery we recommend using solar collec-
tors. Please ask for information from your dealer.

Gas connection

The operating pressure of the unit (30 mbar, see type
plate) must be the same as the gas supply's operating
pressure.
The gas supply line (8 mm dia.) must be attached to gas-con-
nection muff with olive screw fitting. Carefully counterhold
with another spanner when tightening!
The gas connecti on fitting on the appliance is not to be short-
ened or bent.
Prior to connecting the appliance make sure that the gas lines
are free from dirt, chips and such!
Choose to route the pipes in a way that will facilitate removing
the unit for service tasks.
Keep the number of parting connections in the gas supply
line in rooms frequented by people to a technically feasible
minimum.
The gas system must accord with the technical and adminis-
trative provisions of the individual country of use (in Europe,
for example, EN 1949 for motor vehicles or EN ISO 10239 for
boats). National regulations and rulings (in Germany, for exam-
ple, the DVGW worksheet G 607 for motor vehicles or G 608
for boats) must be respected.

Function check

After installation, the gas feed line must be tested for tight-
ness by the pressure-drop method. A test certificate (in Ger-
many, for example, in accordance with DVGW Worksheet
G 607 for motor vehicles or G 608 for boats) is to be issued.
All equipment functions must be tested in accordance with
the user manual after installation.
The operating instructions and completed guarantee card are
to be given to the owner of the vehicle.
Take the nameplate of the operating instructions and
installation instructions and adhere to a place on the ap-
pliance which is clearly visible and protected against damage.
The year of initial operation must be marked on the type plate.

Warning information

The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the
appliance, to a place in the vehicle where it is clearly visible to
all users (e.g. on the wardrobe door)! Ask Truma to send you
stickers, if necessary.