Accessories

1. Control unit VG 2
for heaters of driver's cabs in tank vehicles, for the trans-
portation of hazardous goods according to ADR (not to be
used in combination with a time switch).
2. Outside switch AS
for switching the heater on and off from the outside of the
vehicle, e.g. for cargo space heaters (available with 4 m or
10 m connecting cables).
3. Acoustic signalling device ASM
gives an acoustic signal in event of a failure.
4. Time switch ZUE / ZUE 2
for pre-programming 3 switch-on times within 7 days,
including 4 m connecting cable (suitable for 12 V and 24 V
vehicle electrical system).
ZUE, part no. 39890-00, for installation in existing cut-outs,
suitable for control panel with slide switch.
ZUE 2, part no. 39891-00 with cover frame, suitable for
control panel with rotary switch.
5. Remote sensor FF
monitors the room tem perature independent of the position
of the control panel (available with 4 m or 10 m connecting
cable).
6. Multiple connector MSD
for connecting several accessories (e.g. time switch and
remote sensor).
Extension cable for accessories
items 1 – 6 of 4 m or 10 m (not illustrated).
7. Direct switch DIS
for operating the heater at high setting only, without tem-
perature control (available with 4 m or 10 m connecting
cable). Replaces control panel.
Or direct fixed temperature switch DFS
for operating the heater at a fixed temperature
(40° C – 70° C depending on the version). Replaces the
control panel.
All electrical accessories are fitted with a connector and can
be connected individually.

Technical data

determined in accordance with EN 624 or Truma test
conditions
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see data plate)
Rated thermal output
High setting: 2400 W
Low setting: 1200 W
Gas consumption
High setting: 200 g/h
Low setting: 100 g/h
Air flow rate
High setting: approx. 78 m ³ /h
Low setting: approx. 49 m ³ /h
Current input at 12 V
High setting: 1.1 A
Low setting: 0.6 A
Current input at 24 V
High setting: 0.7 A
Low setting: 0.4 A
Standby
0.01 A
Weight
approx. 4.7 kg
Declaration of conformity
The Trumatic E 2400 has been tested by the DVGW and
complies with the gas equipment directive (90/396/EEC) and
the other applicable EC directives. The following CE Product
Ident. No. is available for EU countries: CE-0085AP0008.
The heater complies with heater directive 2001/56/EC and
supplements 2004/78/EC and 2006/119/EC and bears the type
approval number: e1 00 0144.
The heater complies with the interference suppression
directive 72/245/EEC for vehicle engines with annexes
2004/104/EC, 2005/83/EC and 2006/28/EC and bears type
approval number: e1 03 2605.
The heater complies with EMC directive 89/336/EEC and low
voltage directive 73/23/EEC.
The right to effect technical modifications is reserved!
Dimensions
370
24
123
15