9 and 10 clamps for lock switches
A lock switch can be attached to this clamp block. The system can be
armed and disarmed with the lock switch.
A maximum of 5 lock switches can be attached in parallel.
Note that the attached lock switch should have a switch
function. Switches which are permanently switched on (until
the next activation) are persistent and are thus unsuitable in
this case.
Arming the system
Button contact
First button activation
Second button activation
Disarming the system
Button contact
First button activation
Second button activation
Status
• AWAY-Mode arming
• HOME-Mode arming
Status
• Disarming the system
• The alarm memory is
deleted
• System is now disar-
med
Explanation
• Exit delay starts
• Beep emitted if activated
• When the exit delay time is passed the
alarm system is armed.
• The second button activation must be car-
ried out while the exit delay is active.
• Beep emitted until the exit delay time is
passed.
• When the exit delay time is passed the
alarm system is armed.
Explanation
• The system is disarmed and reset if no
alarm sounds. The alarm system is now
ready to be armed again.
• The system is disarmed but with alarm
memory. Second button activation is re-
quired
• The alarm system is now ready to armed
again