11.3 Deactivating Individual Loops when Arming

Sometimes it is necessary to manually deactivate some loops to arm the alarm control centre. This may
have several causes:
• A loop indicates an error which cannot currently be fixed.
• A loop which is not connected to the HOME mode needs to be deactivated.
• The sabotage contact in the alarm control centre needs to be deactivated so that maintenance work can
be carried out or so that the voice message can be saved.
Ensure also that the alarm control centre is disarmed and that is has not sounded an alarm. In addition, no
loop LED should be lit or flashing.
• Enter one of the 8 programmed user codes.
• Press the "BYPASS" button.
• Press the numbers of the loops which are to be deactivated.
• Press the "#" button for confirmation.
• The "EXIT/ARMED" LED and the deactivated loop LEDs flash during the exit delay time.
• During this time the beeper on the remote control unit may beep (depending on the programming).
• Once the exit delay time has passed, the "EXIT/ARMED" LED is lit, the activated loops continue to flash
and the beeper is silenced.
• The alarm control centre is now armed and the corresponding loops are deactivated.

11.4 Disarming the alarm control centre / resetting alarm outputs

With the user code you can disarm the alarm control centre, reset the alarm outputs and also delete the
loops which were activated in the armed status. Please note the following conditions.

11.4.1 Disarming the alarm control centre / deactivating alarm outputs

If you wish to arm the alarm control centre then enter the following button combination. If the alarm control
centre has sounded an alarm, the currently active outputs (e.g. clamps 7 and 9) and the telephone dialler
will be reset.
• Enter one of the 8 programmed user codes.
• Press the "#" button for confirmation.
• The LEDS for the triggered loop flash and the alarm control centre can no longer be armed using the user
code.
• To extinguish the LED refer to the next chapter.