Herunterladen Inhalt Inhalt Diese Seite drucken

Deleting Alarm Signal (Leds); Deleting Alarm Signal And Rearming Alarm Control Centre; Centralising Remote Control And Status Check By Telephone - Renkforce 751514 Bedienungsanleitung

8-zonen alarmanlagenset mit telefonwählgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

11.11.5 Deleting alarm signal (LEDs)

If the alarm control centre answers the call with 1 + 2 signal tones, this means that the alarm control centre
is disarmed, but an alarm message is present (LEDs for one or more loops are lit).
• Enter user code 1 using a dual tone multifrequency telephone.
*
• Press the "
" button.
• Press button 3.
• Press the # button for confirmation.
• The alarm control centre remains disarmed and the alarm outputs are reset.
• The alarm control centre confirms the change of status with 1 signal tone.
• The LEDs for the corresponding loop are no longer lit on the remote control unit.

11.11.6 Deleting alarm signal and rearming alarm control centre

If the alarm control centre answers the call with 1 + 2 signal tones, this means that the alarm control centre
is disarmed, but an alarm signal is present (LEDs for one or more loops are lit).
• Enter user code 1 using a dual tone multifrequency telephone.
*
• Press the "
" button.
• Press button 6.
• Press the "#" button for confirmation.
• The alarm control centre immediately arms and the alarm outputs are reset.
• The alarm control centre confirms the change of status with 2 signal tones.
• The exit delay time is not observed in this case.
• The LED for the corresponding loop is no longer lit on the remote control unit.

11.11.7 Centralising remote control and status check by telephone

Input (is enter on the control panel)
User code 1 > #
User code 1 > * > 3 > #
User code 1 > * > 6 > #
144
Explanation
- Arming the alarm control centre from disarmed
status.
- Disarming the alarm control centre from armed
status.
- The alarm control centre remains disarmed and
the alarm signals (LEDs) are no longer lit.
- Deleting alarm signal and rearming alarm control
centre.

Werbung