Testing the fourth telephone number:
• Enter one of the 8 programmed user codes.
*
• Press the "
" button.
• Press the "63" button.
• Press the "#" button for confirmation.
Please note the following information for making an alarm telephone call:
• The control panel signals a correct test with two signal tones.
• If the control panel emits 5 signal tones there is an error.
This may have several causes: For example it may be that no telephone number is program-
med to this memory location or that the telephone dialler is not activated.
• If the call is successful the alarm control centre emits the voice message / signal tones.
• The telephone dialler only dials the telephone numbers once. In an alarm situation the number
will be dialled the programmed number of times.

11.10 Room monitoring

You have activated the telephone dialler and saved telephone numbers.
After an alarm, the first telephone number will be called. The alarm control centre plays back the voice
message or the signal tones. After a longer signal tone, the alarm control centre waits approx. 3 seconds
before repeating the voice message or the signal tones. This depends on your programming (see chapter
10.15). Once the programmed number of repetitions of the voice message or the signal tones is completed,
the telephone dialler hangs up and dials the second programmed telephone number. The same process
occurs. Once all telephone numbers have been called, the telephone dialler begins the entire sequence
again, until the number of programmed call sequences is completed (see chapter 10.14).
After the longer signal tone at the end of the voice message or the signal tones, the person called can
interrupt the message and listen to the room by pressing 1 on a dual tone multifrequency phone. He or she
now hears the sounds in the room where the alarm control centre or the external microphone is located for
a set period of time (see chapter 10.17).
This telephone dialler now no longer dials this telephone number. Depending on your programming (see
chapter 10.16) it is possible that the call sequence is now finished.
Telephone call
>
Once the room monitoring time is passed there is another longer signal tone. If you press 1 on the telephone
again within 10 seconds you can listen to the room for the programmed time once again. This process can
be repeated as often as you like.
To make the telephone dialler hang up, press the 9 button after the longer signal tone. The call is ended.
Telephone call
>
Nonetheless, the room monitoring must have been activated at least once (see chapter "10.17
Setting the Room Monitoring Time").
In the following you see several examples of the programming already described (see chapter "10.16 Set-
ting Call Confirmation")