Renkforce 751514 Bedienungsanleitung Seite 96

8-zonen alarmanlagenset mit telefonwählgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7 operating voltage +12 V/DC (e.g. optical signalling device):
This clamp provides +12 V in the case of an alarm until the alarm control
centre is reset using the corresponding code on the remote control, with
a key switch or with an additional code lock on clamps 9 and 10.
It is recommended that these clamps are used to operate op-
tical signalling devices e.g. stroboscopic flashlights.
This clamp has a total maximum loading capacity of 2.5 A,
otherwise the inbuilt fuse will trigger.
8 operating voltage +12 V/DC (e.g. acoustic signalling device):
This clamp supplies constant +12 V/DC until the time set via the corres-
ponding programming mode has passed.
It is recommended that these clamps are used to operate
acoustic signalling devices e.g. sirens.
Please observe the applicable legal and communal regulati-
ons!
In Germany an acoustic alarm signal may only sound for a ma-
ximum of 3 minutes. This time period may, however, vary for
specific communities or locations (e.g. health spas).
This clamp has a total maximum loadingcapacity of 2.5 A,
otherwise the inbuilt fuse will trigger.
The extremely loud alarm sound can damage your hearing if
the device is operated too close to your ears.
96