b) REL
When measuring a reference value, the difference between the held and the momen-
tarily measured value is displayed to you. This special function is particularly helpful
when ascertaining the lower resistance without the sensing leads' resistance, or with
measured magnitudes that alter slowly.
The function is switched on by pressing the 'REL' key. As a result, the REL symbol
appears in the display's top line. When measuring the resistance, the DMM switches
to the highest range. The 'OL' display disappears by pressing the REL key and is set
to '00.000'. You can quit this function by pressing the REL key again.
Advice!
The REL function is only active when numerical values are being displayed. For
example, the function cannot be called up during the continuity test.
c) LIGHT
The background lighting is switched on or off every time the 'LIGHT' key is pressed.
Due to the relatively high power consumption, the illumination should only be swit-
ched on for a short time and switched off again as quickly as possible, in order to
save energy. The illumination will be automatically switched off after approximately
30 seconds if you do not press the key again after switching on.
d) MENU
Press the 'MENU' key. As a result, the so-called sub-functions will appear in the
upper display block. Press the key again and the sub-functions will disappear from
the display again. The following sub-functions can be called up after one another in
the display block: AUTO OFF (automatic switch-off) - RS 232C (switching on the
interface) - MAX (maximum value registration*) - MIN (minimum value registration*) -
+PEAK (positive peak value registration*) - -PEAK (negative peak value registration*)
- AVG (average value registration*) - RECALL (redisplaying stored measured values) -
STORE (storing measured values) - GO/NG (a type of comparative measurement).
The respective sub-function that has been called up will flash. Selection is made by
using the arrow keys (< = back and > = forward). The display block will disappear
again if you press the 'MENU' key once more and you return to the momentary dis-
play.
e) ALT-F
This key supports the selecting of alternative displays or measuring processes. For
example, a decibel measurement can be made during a voltage measurement, or the
automatic range selection (in connection with '>' and '<') can be switched off and the
measuring range (RANGE) can be set manually, etc.
44
c) Marche à suivre pour activer l'interface dans l'appareil de mesure :
Actionner la touche "MENU". "AUTO-OFF" clignote. Le symbole "RS232C" apparaît
en-dessous. Actionner une fois la touche fléchée ">". "RS232C" commence à cli-
gnoter. Actionner la touche "ENTER" pour valider l'entrée. L'interface est désormais
activée. Ce réglage persiste jusqu'à l'arrêt (position "OFF") du multimètre.
d) Conditions système requises
Configuration minimale : processeur 486/586 avec 32 Moctets de RAM, carte gra-
phique Super VGA, lecteur de CD-ROM 4 X et Windows 3.1 ou Windows 95/98.
e) Paramètres de l'interface
Vitesse de transmission : 9600 Baud
Bits de données
: 7
Bits d'arrêt
: 1
Parité
: aucune
Elimination après usage
Si le multimètre numérique ne fonctionne plus alors que son alimentation (pile bloc
de 9 V) et les fusibles sont en ordre de marche, ou s'il n'est plus réparable, il convient
de procéder à son rejet conformément aux prescriptions légales en vigueur.
Dépannage
Avec ce multimètre numérique TRUE RMS VC - 608, vous avez acquis un produit à
la pointe du développement technique et bénéficiant d'une grande sécurité de fonc-
tionnement. Des problèmes ou des dérangements peuvent néanmoins se produire.
Vous trouverez ci-après un certain nombre d'opérations qui vous permettront de
remédier vous-même assez facilement à certains de ces dérangements. Respectez
impérativement les consignes de sécurité !
Défaut
Mesure de courant impossible
Pas d'affichage lorsque
l'appareil est en marche
Cause possible
Les fusibles pour les gammes de courant sont-
ils en ordre de marche ?
Le contact est-il parfait entre les câbles de
mesure et les douilles de mesure ?
Les câbles de mesure sont-ils enfichés dans
les douilles A ou µA/mA et COM ?
La pile est-elle vide ?
L'appareil ne s'est-il pas éteint automatique-
ment au bout de 15 minutes sans actionne-
ment d'une touche ?
93