X3 Input State
X3 Output State
Terminal strip X3 (lower terminal)
See parameter LF.82 for functional description.
Value table:
Display
Valency
Combivis
I5
1
I6
2
I7
4
I8
8
I9
16
I10
32
I11
64
Terminal strip is nonexistent at units in D- and E-housing!
Terminal X3 (lower terminal)
See parameter LF.83 for functional description.
Value table:
Display
Valency
Combivis
O5
1
O7
4
O8
8
O9
16
O10
32
O12
128
O14
1024
O15
4096
Terminal strip is nonexistent at units in D- and E-housing!
Display Parameter
Function
Input signal: contactor control
Set value correction speed: V
Set value crawl speed: V
Set value rated speed: V
Set value inspection speed: V
Set value 1st intermediate speed: V
et value 1st intermediate speed: V
S
Function
Signal: ready overspeed
Relay contact: braking control
Signal: operating freq. warning
Signal: delay control
Relay contact: running open doors
Relay contact: main contactor ctrl.
Signal: DC-monitoring
Signal: motor temperature warning
Input
terminal
X3.1
X3.2
B
X3.3
E
X3.4
N
X3.5
I
X3.6
1
X3.7
1
Output
terminal
X3.13
X3.15/X3.16
X3.14
X3.17
X3.18/X3.19
X3.20/X3.21
X3.22
X3.23
GB-23