Herunterladen Inhalt Inhalt Diese Seite drucken

Display Parameter - KEB COMBIVERT F4-F Lift Version 3.0 Kurzanleitung

Vorschau ausblenden Andere Handbücher für COMBIVERT F4-F Lift Version 3.0:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Display Parameter

5.
Display Parameter
X2 Input State
X2 Output State
GB-22
Terminal X2 (upper terminal)
With the X.2 input state it can be easily checked, whether the input
signals reached the inverter control. Every input (output) has a specific
value. If several inputs are set, the sum of the values is shown.
Value Table:
Display
Valency
Combivis
ST
1
RST
2
F
4
R
8
I1
16
I2
32
I3
64
door drive setpoint setting
Example: Input control release (X2.1) and direction forward (X2.3) are
triggered with 24V .
Display value: 1+4 = 5
Terminal X2 (upper terminal)
With the X.2 output state it can be easily checked, whether the outputs
were set by the inverter control. Every digital output has a specific
value. If several outputs are set at the same time, the sum of the values
is shown.
Value table:
Display
Valency
Combivis
O1
1
O2
2
control inverted
O3
4
control cabinet fan
Function
> G
control release
Reset
direction of travel forward
direction of travel reverse
control mode
door drive active
Function
> G
digital
output signal:
braking control
digital
output signal:
main contactor
main contactor
relay
relay ready-to-operate X2.20/X2.22
collective fault
Input
D + E
terminal
X2.1
X2.2
X2.3
X2.4
X2.5
setpoint selection
X2.6
binary-coded
X2.7
Output
D + E
terminal
X2.8
X2.9
control
overspeed

Quicklinks ausblenden: