1.2 Terminal X3 I/O-Expander (units > G-housing)
Terminal Function
1
Digital input signal: contactor control (see chapter 3.6)
2
Setpoint input correction-speed: V
3
Setpoint input positioning speed: V
4
Setpoint input rated speed: V
5
Setpoint input inspection speed: V
6
Setpoint input intermediate speed 1: V
7
Setpoint input intermediate speed 2: V
8
Option ! do not connect !
9
External supply voltage
10
11
Ground for X3.9 / X3.10
12
13
Output signal: ready / overspeed
14
Output signal: switching frequency warning
15
Output relay contact: braking control
16
17
Output signal: delay control
18
Output relay contact: running open doors
19
20
Output relay contact: main contactor control
21
22
Output signal: DC monitoring
23
Output signal: motor temperature warning
B
E
N
I
1
2
Inputs / Outputs
max. voltage endurance to ground: 100 V
digital inputs for setpoint activation
! only valid with LF.2 = 2 !
max. voltage endurance to ground: 100 V
terminal assignment with binary coded
set value selection see LF.2
+ 24 ... + 30 V external voltage input
for relay outputs on terminal X3
≈ U
/ 500 mA
X3.9 / X3.10
≈ U
/ 500 mA
X3.9 / X3.10
30 V DC / 0,01 ... 1 A
≈ U
/ 500 mA
X3.9 / X3.10
30 V DC / 0,01 ... 1 A
30 V DC / 0,01 ... 1 A
≈ U
/ 500 mA
X3.9 / X3.10
≈ U
/ 500 mA
X3.9 / X3.10
see chapter 3.4
see chapter 3.4
see chapter 3.4
see chapter 3.4
see chapter 3.4
see chapter 3.4
see chapter 3.4
see chapter 3.4
GB-5