Herunterladen Inhalt Inhalt Diese Seite drucken

Connection; Example Connection Diagram For Lift Inverters > G-Housing - KEB COMBIVERT F4-F Lift Version 3.0 Kurzanleitung

Vorschau ausblenden Andere Handbücher für COMBIVERT F4-F Lift Version 3.0:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.

Connection

2.1 Example connection diagram for Lift Inverters > G-housing
M
A
EMC-Filter
I
N
S
ϑ
Motor-
PTC
To switch off the control
release the auxiliary
contacts of both main
contactors or a relay (K
),
Encoder
12
behind the safety circuit,
must be used.
K
12
Direction of travel forward
Direction of travel reverse
L
I
F
Secondary drive active
T
-
Secondary drive setpoint input
C
+24V
O
N
X2.9
T
R
Positioning speed, V
O
L
Intermediate speed 1, V
Intermediate speed 2, V
+24V
+24V
+24V
+PA(++)
PE
L1
L2
L3
OH
ϑ
OH
X4 (15-pole)
Control release
X2.1
K
K
K
11
1
2
RST
X2.2
X2.3
X2.4
Control mode
X2.5
X2.6
X2.7
Contactor control
X3.1
K
K
K
BR
1
2
Correction speed, V
B
X3.2
E
X3.3
Rated speed, V
N
X3.4
Inspection speed, V
I
X3.5
1
X3.6
2
X3.7
X3.9
X3.10
X2.23
Braking resistor
PB
PE
U
V
KEB F4-F
W
Lift V. 3.0A
X5 (9-pole)
Braking
X3.15
control
X3.16
Trigger level for
X3.18
running open doors
X3.19
Main con-
X3.20
tactor control
X3.21
X2.20
Heat sink
tempera-
X2.21
ture level
X2.22
Ready
X3.13
Operating frequency warning
X3.14
Deceleration control
X3.17
DC-monitoring
X3.22
Motor temp. warning
X3.23
Speed diviation-
X2.8
Warning
Main contactor
X2.9
control inverted
X2.11
X3.11
X3.12
* All 24 V relays controlled by the frequency
Connection
M
3 ~
K
K
2
1
Encoder
to the lift
control
X4
K
BR
*
+24V
to the lift control
+24V
K
11
*
+24V
K
Fan
*
+24V
K
Ready
*
to the lift control
to the lift control
to the lift control
to the lift control
X3.1
Ground GND
inverter must have diode are suppression.