Inputs / Outputs
1.
Inputs / Outputs
1.1 Terminal X2 Control Terminals (units > G-housing)
Terminal Function
1
Control Release
2
Reset
3
Direction of travel forward
4
Direction of travel reverse
5
Control Mode
6
Door drive active
7
Door drive setpoint input
8
Digital output signal: speed deviation, warning
9
Digital output signal: main contactor control inverted
10
+ 18 V voltage output
11
Ground for X2.10 and digital inputs/outputs
12
+10 V reference voltage
13
Ground for analog inputs/outputs
14
Analog setpoint input
15
(see parameter LF.2 and An-parameter)
16
Analog input of the load measure for pretorque
(see parameter LF.30, LF.67 and
17
An-parameter)
18
Analog output set speed
19
Analog output actual speed
20
21
Relay output for cabinet fan control (LF.66)
22
23
External voltage supply
GB-4
digital inputs:
noise immunity: 2 kV
±
logic 1:
12...30 V
internal input resistor: approx. 2 kOhm
PNP-logic
see chapter 3.4
see chapter 3.4
+18V (+/- 20%) ; max. 20 mA
! When external voltage is connected to
terminal X2.23 then U
X2.10
+10V (+/- 3%) ; max. 6 mA
Differential voltage input -10V ... +10V
resolution:12 Bit Ri = 40 kOhm
Smoothing time: 2 ms / processing time: 1...3 ms
Differential voltage input -10V ... +10V
resolution:12 Bit Ri = 40 kOhm
Smoothing time: 2 ms / processing time: 1...3 ms
-10V...+10V / resolution: 8 Bit
conditional short-circuit proof ( <1 rpm)
^
0...10V
0...LF.20
30 VDC / 0,01 ... 1 A
see chapter 6.1
+ 24 ... + 30 V external voltage input
for digital outputs on terminal strip X2
≈ ≈ ≈ ≈ ≈ U
!
X2.23
Ri = 100 Ohm