Operation
Example:
Attention !
GB-12
Changes between parameter number and parameter value are done
with the „Function"-key. First a valid password must be entered in LF.0
to change the parameter values.
Display
parameter
number
FUNC.
SPEED
START
ENTER
FUNC.
F/R
SPEED
STOP
The parameter values are changed with the arrow keys.
Do only change values when the lift is stoped (i.e. the control release
is not active).
Changed values must be stored with „Enter". The adjusted parameter
value is accepted when the dot disappears.
After adjustment of parameter EC.7 the inverter must be switched
off and on! After the mains voltage is switched on, the inverter displays
the parameter value of LF.99
If a malfunction occurs during operation, the actual display is overwritten
with an error message. The error message can be reset by pressing
the ENTER key.
By pressing the ENTER key only the errror message in the display is
reset. The present error is displayed further on in the status display
(LF.99). First the cause must be removed to reset the error, and a reset
at terminal X2.2 or power-on-reset must be done.
Display
parameter value
START
ENTER
FUNC.
F/R
SPEED
STOP
ENTER
F/R
Acceptance/
storing
Error
ENTER
F/R
Increase / decrease
the parameter value
START
STOP