Herunterladen Inhalt Inhalt Diese Seite drucken

KEB COMBIVERT F4-F Lift Version 3.0 Kurzanleitung Seite 52

Vorschau ausblenden Andere Handbücher für COMBIVERT F4-F Lift Version 3.0:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Display Parameter
Actual Set Value
Actual Inverter Utilization
Actual Set Speed
Actual Speed
Actual Car Speed
Crawl Distance
Total Path
Error Status in Starting
Procedure
GB-24
Display Value:
Speed:
V=0
Display of the actual inverter utilization in %.
The value shows the actual set speed in rpm, calculated from the
system data.
The value shows the real speed in rpm, only with connected
encoder.
Display of the current speed in m/s; only with connected encoder.
Display of the positioning distance in cm, after a completed ride.
Display of the total path in cm, from releasing to applying the brake.
The parameter shows the fault indications that occur during the starting
process and continuous operation.
Display
Significance
StOP
no setpoint selection
S.Co
setpoint selection without contactor control
S.IO
setpoint selection without control release
S.nC
no current flows on the output side, check the wiring
between motor and inverter
run
starting procedure is completed
See parameter LF.99 for more information about other fault indications.
0
1
2
3
V
V
V
B
E
N
4
5
6
7
V
V
V
V=0
I
1
2

Quicklinks ausblenden: