ELR 9000 Series
Element
Com Timeout
Com Protocols
3.4.3.8
Menu "HMI Setup"
These settings refer exclusively to the control panel (HMI).
Element
Language

Backlight

HMI Lock
Key Sound
Alarm Sound
Status page
EA Elektro-Automatik GmbH
Page 54
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Description
Timeout USB/RS232 (in milliseconds)
Default value: 5, Range: 5...65535
Defines the max. time between two subsequent bytes or blocks of a transferred message.
For more information about the timeout refer to the external programming documentation
"Programming ModBus & SCPI".
Timeout ETH (in seconds)
Default value: 5, Range: 5...65535
Defines the "keep-alive timeout" property of a network connection in seconds. If there
was no command communication between the controlling unit (PC, PLC etc.) and the
device for the adjusted time, it will close the socket connection.
Enables or disables SCPI or ModBus communication protocols for the device. The
change is immediately effective after submitting it with ENTER button. Only one of both
can be disabled.
Description
Selection of the display language. Currently (date: 05-20-2016) available are:
German, English
Additional languages (up to three can be integrated) can be implemented on demand
and installed into the HMI via update. The default then would be English plus one or two
additional language such as Italian, Spanish etc.
The choice here is whether the backlight remains permanently on or if it should be
switched off when no input via screen or rotary knob is made for 60 s. As soon as input
is made, the backlight returns automatically. Furthermore the backlight intensity can be
adjusted here.
See „3.7 Control panel (HMI) lock" on page 66.
Activates or deactivates sounds when touching a touch area in the display. It can usefully
signal that the action has been accepted.
Activates or deactivates the additional acoustic signal of an alarm or user defined event
which has been set to "Action = ALARM". See also „3.6 Alarms and monitoring" on page
63.
Enables/disables two display related options for the main screen with actual and set
values:
Show meter bar: in U/I/P mode, i. e. resistance mode not activated, a meter bar for
0-100% actual values of voltage, current and power is shown. See „3.4.8. The meter bars".
Alternative status page: switches the main screen of the device with its actual and
set values of voltage, current, power and - if activated - resistance to a simpler display
with only voltage and current, plus status. See „3.4.7. Switching the main screen view".
Default setting: both disabled