1.9.7

USB-Port Type B (Back side)

The USB-B port on the back side of the device is provided for communication with the de-
vice and for firmware updates. The included USB cable can be used to connect the device
to a PC (USB 2.0 or 3.0). The driver is delivered on the included medium (USB stick) and
installs a virtual COM port.
The device can be addressed via this port either using the international standard ModBus
protocol or by SCPI language. The device recognises the message protocol used automati-
cally. Details for remote control can be found on the web site of Elektro-Automatik or on the
included medium.
If remote control is in operation the USB port has no priority over either the interface module
(see below) or the analog interface and can, therefore, only be used alternatively to these.
However, monitoring is always available.
1.9.8

Interface module slot

This slot on the back side of the device (only with standard models, units with option
3W installed are different) is available for various modules of the AnyBus CompactCom
(abbr.: ABCC) type of the IF-AB interface series. The following options are available
(date: 05-20-2016):
Article number Name
35400100
IF-AB-CANO
35400101
IF-AB-RS232
35400103
IF-AB-PBUS
35400104
IF-AB-ETH1P
35400105
IF-AB-PNET1P
35400107
IF-AB-MBUS1P
35400108
IF-AB-ETH2P
35400109
IF-AB-MBUS2P
35400110
IF-AB-PNET2P
35400111
IF-AB-CAN
The modules are installed by the user and can be retrofitted without problem. A firmware update of the device may
be necessary in order to recognize and support certain modules.
If remote control is in operation the interface module has no priority over either the USB port or the analog interface
and can, therefore, only be used alternately to these. However, monitoring is always available.
Switch off device before adding or removing modules!
1.9.9

Analog interface

This 15 pole Sub-D socket on the back side of the device is provided for remote control of
the device via analog signals or switching conditions.
If remote control is in operation this analog interface can only be used alternately to the
digital interface. However, monitoring is always available.
The input voltage range of the set values and the output voltage range of the monitor val-
ues, as well as reference voltage level can be switched in the settings menu of the device
between 0-5 V and 0-10 V, in each case for 0-100%.
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Description
CANopen, 1x Sub-D 9pole male
RS 232, 1x Sub-D 9pole male (null modem)
Profibus DP-V1 Slave, 1x Sub-D 9pole female
Ethernet, 1x RJ45
ProfiNET IO, 1x RJ45
ModBus TCP, 1x RJ45
Ethernet, 2x RJ45
ModBus TCP, 2x RJ45
ProfiNET IO, 2x RJ45
CAN, 1x Sub-D 9pole male
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
ELR 9000 Series
www.elektroautomatik.de
ea1974@elektroautomatik.de
Page 31