5
DRO 5
Display: three position display, one speed display
Setting the resolution of the counting function
Setting the counting direction
Linear error compensation
Metric / inches change-over
LCD display status setting
Speed mode setting
Basic value setting
5.1
Keyboard (eight keys)
Function selection key, Enter key
Jog key
Increase or decrease key of the digits
5.2
Operations
5.2.1 Axial function
In the normal display state, press the X, Y or Z key to make the corresponding axial value flash. After
flashing several times, this axis will be cleared.
If the value of the indicator is blinking, press the corresponding axis button again to cancel the operation.
If the displayed value is flashing, press the function button "PROG" again to change the fundamental value
of the axis.
5.2.2 Modification of the basic value of X, Y, Z
After entering this option, the basic value is highlighted and the digital bit is located in the flashing state.
The ↑ ↓ keys are used for changing the digital bit, the ← → keys are used for selecting the digital bit. After
completing the changes, press the "PROG" key to exit the option.
5.3
MENU
The operating modes of the menus are nearly same. The ↑ ↓ keys move the cursor to the specified
options, the "PROG" key is used to select them. For optional items, use the ↑ ↓ keys to select, and the
"PROG" key to exit. For modifying items, use the ↑ ↓ keys to modify the digital bit, use the ← → keys to
select the digital bit, and use the "PROG" key to exit. Press the "PROG" key in multilevel menus to go to
the next menu.
Version 1.0.1 dated 2015-12-17
Selection keys of the axes
Original operating instructions
OPTIMUM
M A S C H I N E N - G E R M A N Y
DRO5
GB