Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting And Error Code - Fuxtec Fx-Rmt84M Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
A-screw (right-hand thread): tighten clockwise
B screw (left-hand thread): tighten counterclockwise
Use a torque wrench set to 40-45 Nm

32. TROUBLESHOOTING AND ERROR CODE

Problem
Starter motor does
not run when
"START" is pressed
Starter motor runs,
but engine does
not start
Motor stops during
operation
Manual_FX-RMT84M_FX-RMT92A_Int24_rev01
Possible cause(s)
Electronic circuit board
blocked
Empty battery
Blown fuse
Poor earthing to the motor
or frame
Interrupted microswitch
connections
Starter motor poorly earthed
Starting conditions not
fulfilled
Faulty fuel supply
Faulty ignition
Blocking by the electronic
circuit board
Separate microswitch
earthing
Empty battery
Remedy / Solution
Turn ignition key to "STOP
Charge battery - replace fuse
(10 A)
Check earthing cables
(especially black cables)
Check the microswitch
connections
Check earthing of the starter
motor
Check whether all start
conditions are met
Check fuel level
Check fuel filter
Fit spark plug cap firmly
Clean spark plug electrodes
and check gap
Turn ignition key to "STOP
Check connections
Charge battery
Check earthing of the motor
76
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fx-rmt92a

Inhaltsverzeichnis