A-screw (right-hand thread): tighten clockwise
•
B screw (left-hand thread): tighten counterclockwise
•
Use a torque wrench set to 40-45 Nm
32. TROUBLESHOOTING AND ERROR CODE
Problem
Starter motor does
not run when
"START" is pressed
Starter motor runs,
but engine does
not start
Motor stops during
operation
Manual_FX-RMT84M_FX-RMT92A_Int24_rev01
Possible cause(s)
•
Electronic circuit board
blocked
•
Empty battery
•
Blown fuse
•
Poor earthing to the motor
or frame
•
Interrupted microswitch
connections
•
Starter motor poorly earthed
•
Starting conditions not
fulfilled
•
Faulty fuel supply
•
Faulty ignition
•
Blocking by the electronic
circuit board
•
Separate microswitch
earthing
•
Empty battery
Remedy / Solution
•
Turn ignition key to "STOP
•
Charge battery - replace fuse
(10 A)
•
Check earthing cables
(especially black cables)
•
Check the microswitch
connections
•
Check earthing of the starter
motor
•
Check whether all start
conditions are met
•
Check fuel level
•
Check fuel filter
•
Fit spark plug cap firmly
•
Clean spark plug electrodes
and check gap
•
Turn ignition key to "STOP
•
Check connections
•
Charge battery
•
Check earthing of the motor
76