AC500-S Sicherheitshandbuch, V1.0.1
8005
Sichere Betriebsart
8006
Position 1
8007
Position 3
8000
Position 2
4.6.6.16

SF_SafetyRequest

Normen
Anforderungen
IEC 60204-1, Ed.
9.2.4 Suspension of safety functions and/or protective measures
5.0: 2003
Where it is necessary to suspend safety functions and/or protective measures (for ex-
ample for setting or maintenance purposes), protection shall be ensured by:
- disabling all other operating (control) modes; and
- other relevant means (see 4.11.9 of ISO 12100-2:2003), that can include, for exam-
ple, one or more of the following:
- limitation of the speed or the power of motion;
- limitation of the range of motion.
EN 954-1:1996
5.4 Manual reset
ISO 12100-2: 2003 4.11.4: Restart following power failure/spontaneous restart
Der Funktionsbaustein repräsentiert die Schnittstelle zwischen Anwenderprogramm und Systemum-
gebung.
Jegliche Vervielfältigung, Verwendung oder Weitergabe an Dritte ist ohne ausdrückliche Genehmigung streng verboten.
© Copyright 2012-2013 ABB. Alle Rechte vorbehalten.
Der Sicherheitsmodus ist aktiv.
Ready
S_EnableSwitchOut
Error
Der Sicherheitsmodus ist aktiv, und der Freigabeschalter ist in
Position 1.
Ready
S_EnableSwitchOut
Error
Der Sicherheitsmodus ist aktiv, und der Freigabeschalter ist in
Position 3.
Ready
S_EnableSwitchOut
Error
Der Sicherheitsmodus ist aktiv, und der Freigabeschalter ist in
Position 2.
Ready
S_EnableSwitchOut
Error
= TRUE
= FALSE
= FALSE
= TRUE
= FALSE
= FALSE
= TRUE
= FALSE
= FALSE
= TRUE
= TRUE
= FALSE