1.2 Technical specifications
Table 1 shows the technical specifications of the products in the range referred to in this manual.
Voltage [VAC] (Tol +10/-
20%)
Inverter power
Phases
supply
Frequency [Hz]
Current [A]
Voltage [VAC] (Tol +10/-
20%)
Phases
Frequency [Hz]
Inverter output
Current [A rms]
Max. power output [kVA]
(400 Vrms)
Mechanical power P2
Unit weight [kg]
Mechanical
(excluding packaging)
specifications
Maximum dimensions
[mm](WxHxD)
Work position
IP protection rating
Max. ambient temperature
[°C]
Max. section of lead
accepted by input and
Installation
output terminals [mm²]
Min. diameter of cable
accepted by input and
output cable glands [mm]
Max. diameter of cable
accepted by input and
output cable glands [mm]
Control and
Pressure regulation range
[bar]
operating
hydraulic
Options
specifications
Type of pressure sensors
Pressure sensor full scale
Sensors
[bar]
Type of flow sensor
supported
Connectivity
Functions and
safety devices
Safety devices
Table 1: Technical specifications
ENGLISH
Technical specifications
MCE-55/P
17,0-13,0
0 - V alim.
7,5 CV / 5,5 kW
Serial interface
Multi inverter connection
Dry running
Current sensitivity on output phases
Temperature overload on internal electronics
Abnormal power supply voltages
Direct shorting between output phases
Fault on pressure sensor
61
MCE-30/P
380-480
3
50/60
3
0-200
13,5
7,0
7,6
267x196x352
Any
55
50
4
11
17
1 – 95% full scale without press.
Flow sensor
Ratiometric / 4:20 mA
16 / 25 / 40
5 pulses [Vpp]
380-480
3
50/60
11,5-9,0
0 - V alim.
3
0-200
7,5
4,0
4,0 CV / 3 kW

Werbung

loading

Diese Anleitung auch für:

Mce-30/p