EMPTYING THE TANK
When not in use, especially in the presence of low temperatu-
res, it is advisable to drain the water present inside the tank.
For the appliance in question, just disconnect the water inlet
connection (see par. "8.7 Hydraulic connections" on page 180).
Alternatively, if you are setting up the system, it is recommended
that you install a drain cock.
NB!: empty the system in case of low tempe-
ratures in order to avoid freezing phenomena.
9.5
REPLACEMENT OF THE POWER CORD
DO NOT TAMPER WITH THE
POWER CORD.
If the power supply cable is dam-
ATTENTION
aged, it must be replaced by the
manufacturer or the technical as-
sistance service or in any case
by a person with similar qualifi-
cations, in order to prevent any
risk.
The cable must be replaced in compliance with the laws in force
in the country where the product is used.
Replace the damaged power cord with a new one with the same
or equivalent characteristics to the original cord.
10. REQUIREMENTS FOR THE
OPERATION, SERVICE AND
INSTALLATION
10.1
GENERAL WARNINGS
Any maintenance operation must
be performed by qualified per-
sonnel in accordance with the in-
OBLIGATION
structions in this manual.
The unit must be placed in a
room that does not have continu-
ous ignition sources (e.g. naked
OBLIGATION
flames, a gas appliance or elec-
tric heater in operation).
Do not pierce or burn.
OBLIGATION
EN
194
EGEA TECH
OBLIGATION
OBLIGATION
10.2
EXPERT TECHNI-
During maintenance operations, the operator in charge must
check the following points.
Installation conditions
Check that:
• The dimensions of the installation compartment are those
specified in this manual.
• Sufficient ventilation of the room is ensured.
• The markings and graphic signs on the product are present
and legible.
• There are no signs of damage or corrosion on the product that
could impair its operation or cause refrigerant gas to escape.
In case of differences in the product installation conditions,
maintenance personnel are required to inform the owner and
proceed with elimination of the non-conformities found.
Checks and repairs of electrical components
Check that:
• There are no conditions of imminent danger for the operator;
• The circuit is not powered.
• If it is not possible to operate without power supply, make
sure the owner has been notified regarding the situation.
• The electric capacitors have been safely discharged without
producing sparks.
cod. 3540000410 - Rev. 03 - 09/2023
200 LT - 260 LT -200 LT-S - 260 LT-S
Remember that refrigerant fluids
may be odorless.
The appliance must be installed,
operated and placed in an instal-
lation compartment with a mini-
mum height of no less than 2 me-
tres.
MAINTENANCE
Any
intervention
equipment must be performed by
qualified personnel. Exclusively
for interventions on the refrige-
ration circuit, including disposal,
the personnel must be equip-
ped with a suitable refrigeration
technician's license aimed at the
CIAN
knowledge and management of
systems containing gases of the
HFC type.