8.7.2 Cascade system plumbing connections
The following figures (fig. 62 - fig. 63 - fig. 64) show 3 examples
of hydraulic connection.
5
11
16 17
11
1
11 10 12 10 17
11
19
fig. 62 - Example of water system WITHOUT thermostatic mixing valve
Legend
1
Inlet tube
4
Recirculation water inlet
5
Hot water outlet pipe
6.
Solenoid valve for recirculation with cascade (nor-
mally open 230Vac-50Hz)
9
Inspectable end of the exhaust pipe
10
Pressure gauge
11
Shut-off valve
Note:
1) The recirculation pump (part.16) must be connected to terminal CN26 of the master motherboard (ref. "fig. 72 - Wiring diagram of the equipment" on page 189).
2) Fit a normally open solenoid valve (part. 19) for each unit in the cascade. The valve must be connected to terminal CN14-1 (ref. "fig. 72 - Wiring diagram of the
equipment" on page 189) of the mother board of each unit.
3) If recirculation is provided, a normally open solenoid valve (part. 6) must also be fitted for each unit in the cascade. The valve must be powered in parallel with the
normally open solenoid valve (part. 19).
EN
182
EGEA TECH
6
11
4
13
14
15
SLAVE
21
12
Pressure regulator
13
Safety valve
14
Expansion vessel
15
Drain cock
16
Recirculation pump
17
Non-return valve
18
Thermostatic mixing valve
19
Solenoid valve for cascade water inlet manage-
cod. 3540000410 - Rev. 03 - 09/2023
200 LT - 260 LT -200 LT-S - 260 LT-S
6
11
11
19
4
13
14
15
SLAVE
21
20
6
11
11
19
4
13
14
15
21
ment (normally open 230Vac-50Hz)
20
Exhaust manifold
21
Siphon
22
Unloading on the ground
Cascade management serial connectionsa
Electrical connections
MASTER
22