Herunterladen Diese Seite drucken

Ferroli EGEA TECH 200 LT Anleitung Für Betrieb, Installation Und Wartung Seite 148

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 330
3.8
CASCADE FUNCTIONALITY
The term cascade is intended to indicate a group of water he-
aters that work together, within which only one Master and se-
veral slaves are identified.
The Master has the task of managing the operation of the units
connected to it.
The electronics of the unit, in fact, allows the unit to be configu-
red both as Master and as Slave.
While managing the cascade, the MASTER can manage three
different levels of operation, depending on the user's request:
1. minimum level of functioning
2. medium level of functioning
3. maximum operating level
Under normal operating conditions, the MASTER has full con-
trol of all Slaves.
It is indeed capable of
manage the operating status of each Slave
modify the setpoint of all the Slaves
modify some parameters of all the Slaves according to its
values
if the solar function is active, inform the Slaves of the tem-
perature read by the PT1000 probe of the solar panel
read the status (e.g. alarms, water temperature, ...) of each
SLAVE
keep the Slave clock updated
NOTE: only from the master display will it be pos-
sible to change the system status, such as set-
point,
operating
mode,
From the display of the SLAVE, on the other hand, it will only be
possible to view its status.
EN
148
EGEA TECH
time
band
programming.
cod. 3540000410 - Rev. 03 - 09/2023
200 LT - 260 LT -200 LT-S - 260 LT-S
3.9
HOW TO ACCESS THE USER AND INSTAL-
LER MENU
In
addition
to
the
the
set-point,
it
is
make some adjustments. Some parameters can be changed by
the user, others only by the installer of the unit. All parameters are
divided into various submenus, according to their functionality.
The menus available are:
Menu
Description
rtc
Time, day, date setting
FAn
Ventilator parameters
HI
Electric heater
phv
Photovoltaic parameters - EVU
SG
Smart Grid parameters
SoL
Solar thermal parameters
rEC
Recirculation pump
AL
Anti-legionella
CAS
Cascade
Sch
Time bands programming
En
Energy monitoring
Inf
Machine status information
rSt
Reset
UtS Menu – brand, range, model,
UtS
serial number display
Level: U=user menu - I=installer menu
To access the menus:
From
the
main
screen,
keys
simultaneously
Enter the 3-digit password: the value must be entered digit by
digit and it is possible to move between them by pressing the
"SET"
key and the selected digit will be displayed flashing.
Then use the + and – keys to modify the value of the digit.
confirm
the
entered
down the "SET"
If the entered password is correct, it will be possible to ac-
cess the visible parameters based on the entered pas-
sword level, vice versa, you will return to the main screen.
Note: when entering the password, it will always be possible to re-
turn to the main screen by pressing the "SET"
User password: 000
Installer password: 234
possibility
of
possible
from
the
User
U
U
U
U
U
U
U
press
the
+
for
at
least
3
password
by
key for at least 3 seconds.
key.
changing
display
Installer
I
I
I
I
I
I
I
I
I
I
I
I
I
I
and
-
seconds.
holding

Werbung

loading