Then press the "SET"
ds to confirm (a beep will confirm the modifica-
tion) or the "ON/OFF"
Carry out the same procedure for time slots 2 (d1b) to 6 (d1F), then
repeat for the following days (d_2=Tuesday, d_3=Wednesday,
d_4=Thursday, d_5=Friday, d_6= Saturday, d_7=Sunday).
Once the programming has been set, it will be possible
to activate or deactivate it via parameter d_0 of the Sch.
The schedule can be more easily set via APP.
Note: between one time slot and the next, the appliance goes
into stand-by.
3.9.4 FAn MENU - FAN AND SILENT MODE SETTING
In this setting it is possible to activate the "silent mode" (for
example during the night) which allows a reduction in the noise
of the appliance; in this condition the performance in terms of
water heating speed may be lower.
To set the fan speed parameter, access the "Fan" menu by
pressing the "SET"
key.
Value
Description
Enable silent mode function
F01
(0=disabled, 1=enabled)
F02 Fan speed in FAN mode
F03 Silent mode fan speed
Level: U=user menu - I=installer menu
To set the fan speed in FAN mode, select the F02 value. By
pressing the "SET"
key again, the default value of the fan
speed will appear.
To enable the silent function, select the F01 value, pressing
the "SET"
key again the value "0" will appear (it means that
the fan works in default conditions), to activate the silent mode
press the "+" and " -" to bring the value to "1". Press the "SET"
key to confirm (a beep will confirm the modification) and
the "ON/OFF"
key to exit the menu.
To set the fan speed in silent mode instead, select the F03
value. By pressing the "SET"
of the fan speed will appear. Decreasing the % value will de-
crease the noise.
EN
150
EGEA TECH
key for 3 secon-
key to exit the menu.
Unit of
default min
max
Level
measure
U / I
-
0
0
1
%
100 10
100
%
50
10
100
key again, the default value
cod. 3540000410 - Rev. 03 - 09/2023
200 LT - 260 LT -200 LT-S - 260 LT-S
3.9.5 ENERGY MONITORING
The Energy Monitoring function al-
lows, through proprietary algorithms,
an estimate of the values of thermal
NOTA
energy produced and of the relative
share of the renewable part and of
the electrical energy absorbed.
The algorithms have been defined
through laboratory tests with the
units operating with standard factory
parameter configuration and in stan-
dard operating conditions as defined
by the EN 16147 standard.
Therefore, the values indicated by
the Energy Monitoring function are
purely indicative and are intended
to make the end user more aware
of consumption based on different
uses (operating mode and setpoint)
and have no purpose of accounting
for the thermal energy produced or
of the electricity consumed.
To view the electricity consumption, the thermal energy produ-
ced and the renewable energy, access the En menu by pres-
I
sing the "SET"
I
the values "E_A", "E_t" will appear and "E_r".
Value
E_A
Energy absorbed
E_t
Thermal energy produced
E_r
Renewable energy
Level: U=user menu - I=installer menu
For each value it is possible to access the sub-menu:
E_A menu
Value
Instantaneous absorbed
EA1 *
energy
EA2
Energy absorbed per day
EA3 *
Energy absorbed weekly
EA4
Monthly absorbed energy
EA5
Yearly absorbed energy
EA6
Total absorbed energy
Level: U=user menu - I=installer menu
E_t menu
Value
Et1 *
Instant thermal energy
Et2
Daily thermal energy
key and scrolling with the "+" and "-" keys,
Description
Description
Unit of measure
Wh / 10 *
Wh
kWh / 10 *
kWh
kWh
kWh x 10**
Description
Unit of measure
Wh / 10 *
Wh
Level
U / I
U / I
U / I
Level
U / I
U / I
U / I
U / I
U / I
U / I
Level
U / I
U / I