9.
REPLACEMENTS
Incorrect repairs may put the
user in serious danger. If your
device needs any repair, con-
ATTENTION
tact the technical assis-
tance service.
Any intervention on the equi-
pment must be performed by
qualified personnel. Exclusi-
vely for interventions on the
refrigeration circuit, including
disposal, the personnel must
be equipped with a suitable
EXPERT TECHNICIAN
refrigeration technician's li-
cense aimed at the knowledge
and management of systems
containing HFC type gases
Before undertaking any main-
tenance operation make sure
the equipment is not and can-
ATTENTION
not accidentally be electrically
powered.
Therefore, turn off the de-
vice and remove the plug
from the socket.
Carrying out repair work on
parts with safety function
compromises safe operation
ATTENTION
of the equipment. Only replace
defective parts with original
spare parts.
EN
192
EGEA TECH
9.1
Proceed as indicated below (reserved for qualified technical per-
sonnel only):
• Disconnect the power to the equipment.
• Remove the top cover of the equipment and then the power
board cover.
• Remove the fuse cap, then the fuse, using a suitable screw-
driver.
• Install a new IEC-60127-2/II certified time-delay 5 A fuse
(T5AL250V), then refit the protective cap.
• Reassemble all the plastics and make sure the equipment is
correctly installed before powering it.
9.2
This equipment has a manual-reset safety thermostat connect-
ed in series with the heating element immersed in water, which
interrupts the power supply in case of overtemperature inside
the tank.
If necessary, proceed as follows to reset the thermostat (re-
served for qualified technical personnel):
• Unplug the product.
• Remove any air ducts.
• Remove the top cover by first undoing the locking screws (fig.
76).
• Remove the front panel and manually reset the tripped safety
thermostat (fig. 77). In case of intervention, the central pin of
the thermostat comes out by about 2 mm.
• Refit the previously removed top cover.
cod. 3540000410 - Rev. 03 - 09/2023
200 LT - 260 LT -200 LT-S - 260 LT-S
POWER BOARD FUSE REPLACEMENT
fig. 75
REPLACEMENT OF ELECTRIC Heater SAFETY
THERMOSTAT