8.7.3 Condensate drain connection
The condensate forming during heat pump operation flows
through a special drain pipe (1/2"G) that passes inside the insu-
lating casing and comes out at the side of the equipment.
It must be connected, via a trap, to a duct so that the conden-
sate can flow regularly (fig. 65).
fig. 65- Examples of condensate drain connection via a trap
200 LT - 260 LT -200 LT-S - 260 LT-S
cod. 3540000410 - Rev. 03 - 09/2023
8.8
Integration with the solar thermal system (only
for mod 200 LT-S e 260 LT-S)
8.8.1 Integration with the standard solar thermal system
The following figure shows how to connect the appliance to a
solar thermal system controlled by a dedicated electronic control
system (not supplied) which has a "dry contact" type output